Air Driven Oxygen Booster
Application:
Air driven oxygen boosters are mainly used for transferring industrial oxygen gas, medical oxygen gas and breathing air, filling medical oxygen cylinder, charging up breathing air cylinder for diving equipment.
Output pressure:
Air driven oxygen booster can provide output pressure up to 50Mpa.
Main features:
1. Air driven oxygen booster adopts corrosion resistant and special O rings for oxygen gas, to ensure the long time service life of the gas booster.
2. All high pressure parts adopt SUS304 stainless steel materials, which is with oxidative resistance.
3. Clean oil-free treatment and dust-free assembly ensure the cleanliness of medical oxygen gas.
4. Air driven, explosion proof, not generating heat, no-spark and no-flame.
5. Light and portable, convenient to maintain and repair.
STA-OL series Air Driven Oxygen Booster
Technical parameters of STA-OL Series booster:
Type | Pressure ratio | Min. gas inlet pressure PA (bar) | Max. gas inlet pressure PA (bar) | Max. gas outlet pressure PB (bar) | Formula to calculate gas outlet pressure PB | Connection: Gas Inlet / Gas outlet (NPT thread) | Max. flow at air drive pressure of 6bar (L/min) |
STA0.6 | 0.6:1 | 0.1 | 4 | 4.8 | 0.6X PL | 1/2 / 1/2 | 1000 ( at PA of 6 bar ) |
STA02 | 2:1 | 1.7 | 16 | 16 | 2X PL | 1/2 / 1/2 | 960(at PA of 6 bar ) |
STA05 | 5:1 | 3.5 | 40 | 40 | 5XPL | 1/2 / 1/2 | 360(at PA of 6 bar ) |
STA10 | 10:1 | 5.5 | 80 | 80 | 10XPL | 1/4/ 1/4 | 196(at PA of 20 bar ) |
STA25 | 25:1 | 10 | 200 | 200 | 25XPL | 1/4/ 1/4 | 81(at PA of 20 bar ) |
STA40 | 40:1 | 15 | 320 | 320 | 40XPL | 1/4/ 1/4 | 49(at PA of 20 bar ) |
STA60 | 60:1 | 25 | 480 | 480 | 60XPL | 1/4/ 1/4 | 61(at PA of 40 bar ) |
STA100 | 100:1 | 35 | 800 | 800 | 100XPL | 1/4/ M14X1.5 | 39(at PA of 40 bar ) |
Note: PL: air drive pressure PA: gas inlet pressure PB: gas outlet pressure
Drive air pressure: 3-8 bar
STD-OL Series Air Driven Oxygen Booster
Technical parameters of STD-OL Series booster:
Type | Pressure ratio | Min. gas inlet pressure PA (bar) | Max. gas inlet pressure PA (bar) | Max. gas outlet pressure PB (bar) | Formula to calculate gas outlet pressure PB | Connection: Gas Inlet / Gas outlet (NPT thread) | Max. flow at air drive pressure of 6bar (L/min) |
STD04 | 4:1 | 2 | 32 | 32 | 4XPL+ PA | 1/2/1/2 | 380 (at PA of 6 bar) |
STD06 | 6:1 | 4 | 48 | 48 | 6XPL+ PA | 3/8/3/8 | 360 ( at PA of 6 bar) |
STD10 | 10:1 | 5 | 80 | 80 | 10XPL+ PA | 1/4/1/4 | 372(at PA of 6 bar ) |
STD25 | 25:1 | 10 | 200 | 200 | 25XPL+ PA | 1/4/1/4 | 154(at PA of 20 bar ) |
STD40 | 40:1 | 15 | 320 | 320 | 40XPL+ PA | 1/4/1/4 | 92(at PA of 20 bar ) |
STD60 | 60:1 | 25 | 480 | 480 | 60XPL+ PA | 1/4/1/4 | 115(at PA of 40 bar ) |
STD100 | 100:1 | 35 | 800 | 800 | 100XPL+ PA | 1/4/M14X1.5 | 74(at PA of 40 bar ) |
Note: PL: air drive pressure PA: gas inlet pressure PB: gas outlet pressure
Drive air pressure: 3-8 bar
STT-OL Series Air Driven Oxygen Booster
Technical parameters of STT-OL Series booster:
Type | Pressure ratio | Min. gas inlet pressure PA(bar) | Max. gas Inlet pressure PA(bar) | Max.gas outlet pressure PB(bar) | Formula to calculate gas outlet pressure PB | Connection: Gas Inlet / Gas outlet(NPT tread) | Max. flow at air drive pressure of 6 bar (L/min) |
STT25 | 25:1 | 0.1 | 10 | 200 | 25XPL+3.5XPA | 1/4/ 1/4 | |
STT40 | 40:1 | 0.1 | 10 | 320 | 40XPL+ 6XPA | 1/4/ 1/4 | 124(at PA of 8 bar ) |
STT10/60 | 10:1/60:1 | 0.1 | 10 | 480 | 60XPL+6X PA | 1/4/ 1/4 | 84(at PA of 8 bar ) |
STT25/60 | 25:1/60:1 | 10 | 25 | 480 | 60XPL+2.5XPA | 1/4/ 1/4 | 80(at PA of 15 bar ) |
STT100 | 100:1 | 0.1 | 10 | 800 | 100XPL+10XPA | 3/8/ M14X1.5 | 63(at PA of 8 bar ) |
Note: PL: air drive pressure PA: gas inlet pressure PB: gas outlet pressure
Drive air pressure: 3-8 bar